Product Medical Fibers optics product is one the main product of SABA LASE THECHNOLOGIES INC. Product Medical Fibers for Holmium laser enucleation of the prostate (HoLEP) which is a minimally invasive method with ball tip fiber probe 600 micron, for treating benign prostatic hypertrophy for enlarged prostate. this ball shaped fiber normally in 400microns diameter applies for lumbar disc herniation Laser treatment. Curved Ball or deflected ball in some cases named angled ball Fiber surgical probe also uses for laser enucleation of the prostate in case of enlarge prostate or cancerous prostate. : Disposable Ophthalmic Endo Probes Disposable Polyimide Coated- Single ring Radial Fiber Reusable Polyimide Coated Single Ring Radial Fiber Reusable Bare Fiber dentistry Diffused Fiber Laser Probe So Side fire fibers are very common in hemorrhoids surgeries. Diffused fiber is common product of SABA LASE TECHNOLOGIES which uniquely diffuse laser power along a specific length of fiber. Hemorrhoids laser surgery has less pain and less surgery time that bring less rehabilitation time in consequence. Dome shape fiber 600 micron could easily more in the veins and urinary tracks. Dome shape fiber is very similar to flat fiber in performance but better handling. Another key point is F-SMA fiber connector for medical LASER Applications. But the SMA-905 Amphenol standard connector is possible. High quality fiber surgery disposable and reusable probes producer. Fiber numerical Apertures NA is from 0.22 and more. Polyimide coated fibers and ETFE coated fibers 200/230, 300/330, 400/430, 600/630, 1000/1100 micron are available with high standard CE-MDR and bio- compatible. We uses Quarts dome shape cap for beam profile protection during surgery. So we can do customization by adding quarts cap protector and bio-compatible laser pad printing. Our laser Diode products include 1470nm laser and 980 nanometer wavelength laser with almost 30W power. Medical module diodes have a user friendly android 11 base software with safety footswitch which enables the surgeon a full control of the laser operation. Finally new 1940nm wavelength laser diode with 15W power deliver better efficiency for endo vascular laser treatment (EVLT).
Ball Fiber
Customized single use Ball tip Fiber for Percutaneous Laser Disk Decompression (PLDD)
Percutaneous Laser Disk Decompression (PLDD) is one of the so-called “minimally invasive” treatment modalities for contained lumbar disk herniation. The treatment is performed percutaneously, so morbidity is expected to be lower and convalescence period is postulated to be shorter than for conventional surgery. Because of the minimally invasive nature, return to work is usually possible within a few days after treatment.
Properties |
|
Fiber type |
400um bare fiber |
Fiber length |
3m |
Connector type |
SMA905 or HP-SMA905 |
Distal tip Sterilization |
Ball tip EtO-sterilized |
Optional features
- extension sleeve available in various colors
- Laser inscription possible
- Customer-optimized designs on request
- Various accessories available
Core ф [µm] |
Clad ф [µm] |
Outer ф (fiber) [µm] |
NA |
200 |
240 |
265 |
0.22 |
400 |
440 |
465 |
0.22 |
600 |
660 |
685 |
0.22 |
Certifications & approvals: (Completed)
Our production processes, devices and procedures is certified by ISO 13485 .
Iran national medical device directorate.
Produced more than 1500Pcs. And we are capable of producing more than 500Pcs/month.
Disposable Ophthalmic Endo Probes
Bio compatible fibers made of silica in flat polished cannulas and assembled in an ergonomic hand piece for all typical ophthalmic laser devices.
Properties |
|
Wavelength |
Compatible with standard Ophthalmic laser |
Fiber type |
200um core fiber |
Fiber length |
3m |
Connector type |
SMA905 connector or F-SMA (DORC,ALCON,ZIESS) compatible |
Gauge |
20G, 23G, 25G, 27G |
Distal tip NA |
Flat and finished with Nano lapping process 0.22 |
Clinical Tests has done by a group of specialized in ophthalmology and sub-specialized in diseases and surgery of the vitreous body of the eye and the retina. (Iran, Oct. 2021).
Laser beam quality test, here the uniformity of the fiber probe checked @530nm
Certifications & approvals: (In Progress)
Our production processes, devices and procedures is certified by ISO 13485 .
And Iran national medical device directorate (IMED)
Disposable Polyimide Coated Single ring Radial Fiber
A single ring 400um to 600 um shaped fiber guarantee very high mechanical stability and excellent beam quality.
Properties |
|
Fiber type Loose Tube |
400 and 600um Colored Hytrel or without loose tube |
Fiber length |
2m |
Connector type |
SMA905 connector or HP-SMA905 |
Distal tip NA Sterilization |
Encapsulated angled tip 0.22 EtO-sterilized |
Application
Vascular, plastic, gynecological and ENT surgery
Hemorrhoids and fistulas, Endo-Lift.
Optional features
- extension sleeve available in various colors
- Laser inscription possible
- Customer-optimized designs on request
- Various accessories available
Core ф [µm] |
Clad ф [µm] |
Outer ф (fiber) [µm] |
NA |
200 |
240 |
265 |
0.22 |
400 |
440 |
465 |
0.22 |
600 |
660 |
685 |
0.22 |
Clinical Tests has done by a group of specialized in diseases and laser surgery of the hemorrhoids and fistulas . (Iran, Nov. 2021). Results has been satisfactory on more than 40s patients.
Certifications & approvals: (In Progress)
Our production processes, devices and procedures is certified by ISO 13485 .
And Iran national medical device directorate (IMED)
Reusable Polyimide Coated Single Ring Radial Fiber
A single ring radial fiber precisely covered by a dome shaped fused silica capillary tube protecting the radial tip during surgery and facilitates the fiber tip movement through veins. This cap also protects the fiber tip from carbonization and keeps the fiber efficiency for several surgeries. This probe can easily penetrate inside the veins, thanks for no sharp and brittle edge on the probe.
Properties |
|
Fiber type Loose Tube |
400 and 600um Colored Hytrel or without loose tube |
Fiber length |
2m |
Connector type |
SMA905 connector or HP-SMA905 |
Distal tip NA Sterilization |
Encapsulated angled tip 0.22 EtO-sterilized |
Application
Vascular, plastic, gynecological and ENT surgery
Hemorrhoids and fistulas
Optional features
- extension sleeve available in various colors
- Laser inscription possible
- Customer-optimized designs on request
- Various accessories available
Core ф [µm] |
Clad ф [µm] |
Outer ф (fiber) [µm] |
NA |
400 |
440 |
465 |
0.22 |
600 |
660 |
685 |
0.22 |
Certifications & approvals: (In Progress)
Our production processes, devices and procedures is certified by ISO 13485 .
And Iran national medical device directorate (IMED)
Reusable Bare Fiber dentistry
Autoclavable polyimide fibers with biocompatible protection tube (ф2 mm)
guarantee very high mechanical stability and excellent beam quality
Dental laser handpieces have standard SMA905 or FC connector could match the mainstream laser machines, including Biolase Laser, Denlase Laser, Doctor Smile.
Optional features
- Autoclavable
- Available with Germanium-doped silica / silica fibers(NA = 0.37)
- Customer-optimized designs on request
- Customer-specific connectors can be assembled
- Various accessories available
Core ф [µm] |
Clad ф [µm] |
Outer ф (fiber) [µm] |
NA |
200 |
240 |
265 |
0.22 |
400 |
440 |
465 |
0.22 |
600 |
660 |
685 |
0.22 |
Periodontal therapy:
Gingivitis, Periodontitis, Operculectomy, Frenectomy, Gingivectomy
Endodontics:
Root canal sterilization, Peri l abscess, Caries, Desensitization, Laser analgesia
Oral surgery:
Soft tissue excision, Ablation, Implant exposure, Peri-implantitis, Apthae and herpes
Aesthetic procedures:
Bleaching, Depigmentation, Gummy smile correction, Aphthae and herpes, Crown lengthening
Bio stimulation:
Teeth desensitization, Post extraction, TMJ, Haemostats, Leukoplakia
Certifications & approvals: (In Progress)
Diffused Fiber Laser Probe:
This specific laser fiber allows the treatment of a wider range of tumors with a single treatment and overcomes the limitations of currently available laser fibers, such as the limited achievable lesion sizes due the maximum power that can be used without carbonizing tissue.
Applications:
- Hemorrhoids and fistulas
- Tumor ablation
Clinical Tests has done by a group of specialized and sub-specialized in diseases and surgery of the.
Hemorrhoids and fistulas. This fiber is the best choice for tumor ablation and fistulas.
Core ф [µm] |
Clad ф [µm] |
Outer ф (fiber) [µm] |
NA |
200 |
240 |
265 |
0.22 |
400 |
440 |
465 |
0.22 |
600 |
660 |
685 |
0.22 |
Certifications & approvals: (In Progress)
Our production processes, devices and procedures is certified by ISO 13485 .
And Iran national medical device directorate (IMED)
Curved Ball Fiber surgical probe:
Our state-of-the art laser BPH fiber optics probe, utilizes a curved ball at the end of the fiber to perform either coagulation or vaporization of the prostate. Side emitting nature of this probe facilitates the surgeon to work with it in contact mode. This fiber completely delivers the laser energy to the prostate tissue without any additional scattered light.
Core ф [µm] |
Clad ф [µm] |
Outer ф (fiber) [µm] |
NA |
400 |
440 |
465 |
0.22 |
600 |
660 |
685 |
0.22 |
New Product which is under primitive blood and tissue compatibility tests.