single use Ball tip Fiber 600/400um is SABA LASE TECHNOLOGIES routine product. single use Ball tip Fiber probe is very common is some kind of surgeries. Disposable sphere tip Fiber completely focuses laser energy in some microns away from the fiber tip so it could be very effective . Rounded shape of ball tip fiber makes it a good candidate for urological surgeons. It could smoothly move during surgery and get a better handling. Specially in laser enucleation of the prostate (HoLEP). Using a laser with a ball tip fiber to remove prostate tissue that is blocking urine flow. This surgery is similar to open prostate surgery but requires no incisions. This is the last solution for an enlarged prostate — a condition known as benign prostatic hyperplasia (BPH). The fiber type for this kind of surgery is high and up to 600 microns. The fiber type SABA LASE TECH. uses is high quality 600/630 microns fiber from LGO. Surgeons use Ball tip fiber 400microns for Percutaneous Laser Disk Decompression (PLDD). PLDD works by evaporating water in the nucleus pulposus, the inner core of the vertebral disc. The fiber type is according to type of surgery and is possible from 200 microns up to 800 microns. For fiber coating both polyimide coated and ETFE coated fiber are possible. Any additional laser bio compatible marking on the ETFE coating fibers is possible. This could be a ruler pattern on some thing like this. Laser inscription possible. Extension sleeve available in various colors. Customer-optimized designs on request. Various accessories available. SMA905 or HP-SMA905 is connector types. Ethylene Oxide-sterilized is possible(ETO). Certification ISO13485 is possible. Fiber Numerical aperture(NA=0.22) 0.22 and higher is possible. SABA LASE TECHNOLOGIES uses the latest technology to produces ball tip fibers for medical applications. Ball tip surgery fibers is high in quality and the diameter of ball tip fiber can be precisely controlled.
Disposable
Ball Tip Fiber
Single use Ball tip Fiber 600/400um is SABA LASE TECHNOLOGIES routine product. This kind of medical fiber probe is very common in some kind of surgeries. It completely focuses laser energy in some microns away from the fiber tip so it could effectively delivers laser energy to a smaller area, and starts fiber fuse process. In this way glass media, directly changes the laser energy to heat. On top of that, rounded shape of ball tip fiber makes it a good candidate for urological surgeons. It could smoothly move during surgery and get a better handling during surgery. Ball tip fiber 400microns also uses for Percutaneous Laser Disk Decompression (PLDD). In this way laser energy evaporates water content in the nucleus pulposus, the inner core of the vertebral disc. Our possible options for Ball tip fiber types are from 200 microns diameter up to 800 microns. For fiber coating also both polyimide coated and ETFE coated fiber are possible. For better fiber length control during surgery additional laser bio- compatible marking on the ETFE coating fibers is possible according to request.
Properties |
|
Fiber type |
800/600/400um Bare Fiber |
Fiber length |
3m/Customized |
Connector type |
SMA905/HP-SMA905 |
Distal tip Sterilization |
Ball tip EtO-sterilized |
Optional features
- extension sleeve available in various colors
- Laser inscription possible
- Customer-optimized designs on request
- Various accessories available
Core ф [µm] |
Clad ф [µm] |
Outer ф (fiber) [µm] |
NA |
200 |
240 |
265 |
0.22 |
400 |
440 |
465 |
0.22 |
600 |
660 |
685 |
0.22 |
Certifications & approvals:
Our production processes, devices and procedures is certified by ISO 13485 .